The display reads: (1...4 = display fields) |
–
| Check the target value for sender 1 -G79- at idling limit in display field 3. Target value: 12...97 % |
–
| Check the target value for sender 2 -G185- at idling limit in display field 4. Target value: 4...49 % |
Note! The engine control unit converts the angle sender voltage values expressed in percentages corresponding to 5 volts and shows the percentages. (5 volts of voltage supply correspond to 100 %.) |
–
| Slowly depress the accelerator pedal to full gas, watching the percentages displayed in displays fields 3 and 4: |
The percentage in display field 3 should rise steadily. Not the whole tolerance range of 12...97 % is used. |
The percentage in display field 4 should rise steadily. Not the whole tolerance range of 4...49 % is used. |
Note! The value in display field 3 should always be more or less double the value in display field 4. |
If the final target value is not reached: |
–
| Press 0 and 6 for the function “End data transmission” and press Q to confirm the entry. |
–
| Switch off the ignition. |
–
| Adjust the accelerator pedal position sender → Chapter. |
If the display does not change or only changes irregularly: |
–
| Test the accelerator pedal position sender as follows: |
–
| Press 0 and 6 for the function “End data transmission” and press Q to confirm the entry. |
–
| Remove the lining under the steering column: |
|
|
Read measurement value block 62 -> | 1 2 3 4 |
|