| Release hose clip -3-, lift retaining clip -2- and detach coolant hoses. |
–
| Remove bolt -1- and pull coolant pipe (bottom left) off 4/2-way valve. |
Reassembly is carried out in the reverse order; note the following: |
Note t
| Secure all hose connections with the correct type of hose clips (same as original equipment) → Parts catalogue. |
–
| Install air hoses with screw-type clips → Fig.. |
–
| Connect coolant hose with plug-in connector to coolant pipe → Fig. |
|
|
|