| Pull connector -2- on the coolant temperature sender at radiator outlet off -G83- . |
Note Place a cloth underneath to catch escaping coolant. |
–
| Pull off retaining clip -1- and pull coolant temperature sender at radiator outlet -G83- out of screw connection of coolant pipe. |
Installation is carried out in the reverse order; note the following: |
Note t
| Insert new radiator outlet coolant temperature sender -G83- immediately into coolant pipe to avoid loss of coolant. |
–
| Check coolant level and top up if necessary → Chapter. |
|
|
|