Disconnect the coolant hoses that lead to the evaporator together with the clips -3093-.
WARNING
Gas may escape when opening the gas line. Wear safety goggles and appropriate clothing to avoid injury to eyes and burns. Wind the separation point in a rag and open carefully.
–
Loosen the screw connection -arrow- of the gas line -1- on the gas inlet of the filer housing using a hollow bolt.
–
Disconnect the plug connection -1- for the solenoid valve.
–
Loosen the bracket -2- and and remove the gas hose.
–
Unscrew the bolts -arrows- and remove the evaporator.
–
Remove the vacuum line -1- and the coolant hose -2- from the evaporator.