| Check specification of sender 1 -G79- at idling stop in display zone 3: Specification: 3 … 100 %. |
–
| Check specification of sender 2 -G185- at idling stop in display zone 4: Specification: 3 … 100 %. |
Note! The engine control unit calculates the voltage values of the angle sender in percent relative to 5 Volt and displays these as a percentage figure (5 Volt supply voltage equates to 100 %). |
–
| Operate the accelerator pedal slowly until fully depressed and observe the percentage figures in display zones 3 and 4: Specification: 3 … 100%. |
Note! The percent figures in display zone 3 and 4 must rise evenly. The tolerance range is not covered completely. |
–
| Press keys 0 and 6 for the “End output” function and confirm input with the Q key. |
If the ideal value is not measured: |
–
| Check accelerator pedal position sender voltage supply and wiring connections → Chapter. |
|
|
Read measured value block 62 -> | 1 2 3 4 |
|