If display reads -40 ?C, continue test as follows: > < Check conditions
Test sequence
Test sequence
–  Connect fault reader -V.A.G 1551- (-V.A.G 1552-). Switch on ignition and use address word 01 to select engine control unit. (Connecting fault reader and selecting engine control unit → Vehicle diagnosis, testing and information system VAS 5051.)
   
Indicated on display:
–  Press keys 0 and 8 for the function “Read measured value block” and confirm entry with Q key.
 
Rapid data transfer                 HELP
Select function XX                      
Indicated on display:
–  Press keys 0, 0 and 2 for “Display group number 2” and confirm entry with Q key.
 
Read measured value block               
Input display group number XXX          
Indicated on display: (1...4 = Display fields)
–  Read off intake air temperature value in display zone 4.
 
Read measured value block            2 →
Displayed
value
CauseContinue checking
-40 °COpen circuit or short to positive → Chapter
120 °CShort to earth → Chapter
Approx. ambient temperature → Note--- → Chapter

1)  If a temperature is displayed which is below the ambient air temperature of the sender, check sender wiring for transfer resistances. Note when doing this that sender is heated from external sources, e.g. radiated heat when engine is not running.
   

If display reads -40 ?C, continue test as follows: > < Check conditions