seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Fault reader: consulting and erasing the fault memory > < Selectable functions when using the V.A.G?1551/1552 fault reader
Fault reader V.A.G 1551: connecting and selecting the engine electronics control unit
Fault reader -V.A.G 1551-: connecting and selecting the engine electronics control unit
Special tools and workshop equipment required
   
t  Fault reader -V.A.G 1551-
t  Cable -V.A.G 1551/3B-
  Note
The equipment -V.A.G 1552- may be used instead of the -V.A.G 1551-, however in this case the results cannot be printed.
Test conditions
l  Battery voltage, 11 V minimum
l  Correct fuse 21
l  Earth connections to the gearbox, front, or the cylinder head must be correct
l  Air conditioning, OFF
Operation sequence
–  Remove the shelf from the driver side of the vehicle.
  W00-0459
–  Connect the fault reader -V.A.G 1551- using the cable -V.A.G 1551/3B-.
–  According to the required function, the ignition must be connected or the engine started → Chapter, table “Selectable functions”.
  Note
t  If the display indications that normally accompany the operation sequence are not displayed: → Fault reader operating instructions
t  If a keying error causes the following message to appear, “Data transmission error”, the fault reader cable must be disconnected and reconnected, then, the sequence of operations is repeated
  E01-0124
Display indication:
 
V.A.G - SELF DIAGNOSIS              HELP
1 - Rapid data transmission             
or
appear alternating
–  Operate the fault reader taking into account the message displayed on the screen:
–  Press key 1 for “Rapid date transmission”.
–  Press the keys 0 and 1 for the address code “Engine electronics”, confirm using the key Q.
 
V.A.G - SELF DIAGNOSIS              HELP
2 - Intermittent code emission          
Display indication:
t  6K0 907 311 X = control unit part number (Refer to the Spare Parts Catalogue to find out the version of the control unit fitted)
t  MONO 1.2.3 = System designation
t  DGC = Program version
t  Code 01 = code version
–  Press the key .
 
6K0907311X 1,6 l R4 MONO 1.2.3 DGC      
Code 01                                 
Display indication:
–  Continue confirmation of repair descriptions.
 
Rapid data transmission             HELP
Select the function XX                  

Fault reader: consulting and erasing the fault memory > < Selectable functions when using the V.A.G?1551/1552 fault reader