Display and evaluation of individual values in display group 005: > < Display and evaluation of individual values in display group 003:
Display and evaluation of individual values in display group 004:
   
Display and evaluation of individual values in display group 004:
Display group 004
Read measured
value block 4
Indicated on display  
xxxxxxxxxxxx   
1234Display zonesTarget valueEvaluation
    Status of telephone mute“On” or “off”See table below
   Telephone“Telephone” 
  empty → Note  
 Status of control output active amplifier (DSP)“0” 

1)  here, 'empty' means that there is nothing in the display zone
   
Display zoneDesignationDisplay contentsFault elimination
1Status of control output active amplifier (DSP)Control output is OK = Display “0”
Control output is not OK = Display “1”
–  Visual check of wiring
–  Check electrical connections of relevant circuit to ensure they are securely and correctly connected, and monitor display at the same time
–  If the display contents do not change upon operation, rectify the fault or renew the relevant component
–  Perform a function test
–  Interrogate the fault memory again
2Noneempty → Note 
3Telephone“Telephone” 
4Status of telephone mute (pin 2 of multi-pin connector III)Input is active = Display “on”
Input is inactive = Display “off”
 

2)  here, 'empty' means that there is nothing in the display zone
   

Display and evaluation of individual values in display group 005: > < Display and evaluation of individual values in display group 003: