| Battery charger -VAS 5095 A- |
Warning t
| Always set battery type 2.4 V/C (Volt/Cells) when in support mode! This applies for all batteries. |
t
| The battery charger -VAS 5095 A- terminal clamps must remain in contact with the battery terminal clamps whilst the battery is being exchanged. |
|
–
| Switch off ignition and all electrical consumers. |
–
| Set support mode/normal mode change-over switch to “support mode” → Chapter. |
–
| Connect red terminal clamp “+” of charger unit to positive terminal of vehicle. |
–
| Connect black terminal clamp “-” of charger unit to negative terminal of vehicle. |
–
| Check setting for battery type on type of battery switch → Chapter. Must be set to 2.4 V/C (Volt/Cells). |
The yellow LEDs → Fig.-6- and -3- light up. |
Note! t
| A minimum load of 0.6 A (e.g. parking light) must be switched on, otherwise support mode is not possible. |
t
| During the support mode the current draw is limited to 5 A. |
–
| Switch on vehicle parking light. |
–
| Remove charger unit terminals from battery terminals. |
–
| Set support mode/normal mode change-over switch to “normal mode” again → Chapter. |
|
|
|