| Battery charger -VAS 5095 A- |
Warning Always set battery type 2.4 V/C (Volt/Cells) when charging! This applies for all batteries. |
|
Note! t
| The battery must have a temperature of at least 10 °C. |
t
| If the battery has cell sealing plugs, do not open them while the battery is being charged. |
–
| Switch off ignition and all electrical consumers. |
–
| Check setting for battery type on type of battery switch → Chapter. Must be set to 2.4 V/C (Volt/Cells). |
–
| Connect red terminal clamp “+” of charger unit to positive terminal on battery. |
–
| Connect black terminal clamp “-” of charger unit to negative terminal on battery. |
The charging current indicators → Fig.-2- and -3- light up yellow. When only the light emitting diode (LED) -3- lights up yellow, battery is partially discharged (approx. 90 %). |
If the LED lights up green → Fig.-4- the charger has switched to "maintaining charge". The battery is fully charged. |
–