| Follow route of wiring connector -1- and unclip from reservoir. |
–
| To release, twist securing clip on hose connection -3- and pull off elbow connector from headlight washer system pump -V11--2-. |
–
| Collect escaping fluid in a suitable container. |
–
| Pull headlight washer system pump -V11--2- upwards out of rubber seal in reservoir and release and separate connector -1-. |
For fitting, the operations are carried out in reverse order to the removal, taking the following into account: |
–
| On completion of installation work, bleed headlight washer system → Chapter. |
|
|
|