Overview of the operating unit: |
1 - | Displays charging status 25 %. |
2 - | Displays charging status 50 %. |
3 - | Displays charging status 75 %. |
4 - | Displays charging status 100 %. |
6 - | Button Start / Stop and Setup to cancel the charging procedure and re-establish. Access to the Setup menu and selection of the characteristic curve type (press for 10 seconds). |
7 - | Displays irregularities. |
–
| Place the charging device in the engine compartment or under the vehicle. |
–
| Connect the power cable to the charging device and the power supply. |
Charger is in no-load operation - ready light is on. |
WARNING Injury risk! Observe safety precautions → Chapter. |
|
–
| Connect the red charging cable to the positive battery terminal „+“. |
Note On vehicles with Start / Stop function and battery monitor control unit -J367-, the black charging terminal - must be connected to the body earthing. Connecting it to battery negative terminal will cause start/stop system to malfunction. |
–
| Connect the black charging cable to the negative battery terminal „-“. |
The charging begins after approx. 2 seconds. |
The LEDs show the charging status of the battery. When all lamps have illuminated, the battery is charged. |
Once the battery is charged, the battery charger -VAS 5906- switches automatically to retention mode. |
Caution There is a risk of spark generation when the charging terminals are removed too early. The charging stops by tapping on the Start / Stop button. |
|
–
| For ending the charging procedure, press the button Start / Stop button. |
–
| Remove the black charging cable from the negative battery terminal „-“. |
–
| Remove the red charging cable from the positive battery terminal „+“. |
|
|
|