t
| Battery tester with printer -VAS 5097 A- |
Note Take into account the TPI 2012182 in relation to the battery tester with printer -VAS 5097 A-. |
To carry out a discharge test of the battery: |
WARNING The batteries whose magic eye a clear yellow or clear colour should not be tested nor charged. Do not perform an auxillary start. |
The risk of explosion exists upon testing and charging or performing an auxillary start. |
These batteries must be renewed. |
|
Note The battery must have a temperature of at least 10 °C. |
–
| Turn off the ignition and all electricity consumers. |
–
| On batteries that are equipped with a colour indicator, check the latter → Chapter. |
–
| Check the cold test current according to the specific data about the battery in amperes (A) according to DIN or determine with the help of the table → Chapter „Table: Cold discharge test current“ the adjustment margin for the battery tester with printer -VAS 5097 A-. |
Note –
| Adjust the cold testing current using the cold current selector → Chapter. |
–
| With the ON/OFF function selector the measurement range must be adjusted: 80 - 379 A or 380 - 499 A → Chapter. |
Note Batteries with a low temperature test current more than 499A according to DIN (e.g. 520A, 580A or 600A) can be checked provisionally with the setting for 499A according to DIN. |
–
| Connect the red terminal „+“ of the tester to the positive pole. |
–
| Connect the black terminal „-“ of the tester to the negative pole. |
Note t
| Ensure the perfect connection of the tester terminal clamps. |
t
| Take into account the TPI 2012182 in relation to the battery tester with printer -VAS 5097 A-. |
|
|
|