Inspecting proper operation and power supply
Inspecting proper operation and power supply
Test conditions
l  Battery voltage at least 11.5 volts
   
l  Fuse no. 30 in fuse holder below the dash panel O.K.
–  Fold rear seat forwards.
–  Remove the cover from the fuel delivery unit.
–  Switch on ignition. The fuel pump must be heard to start running.
–  Switch off ignition.
If the fuel pump does not run:
–  Remove cover from the fuse holder.
–  Remove fuse No. 30 from the fuse holder.
–  Connect remote control -V.A.G 1348/3A- with the adapter cable combination from the adapter cable set to fuse socket no. 30 and to battery positive (+).
–  Activate remote control.
If the fuel pump starts running:
–  Testing fuel pump relay -J17- → Vehicle diagnosis, testing and information system VAS 5051.
If the fuel pump does not run:
–  Disconnect the plug from the flange at the fuel delivery unit.
Vehicles ? 03.10
  S20-0290
–  Connect multimeter for voltage measurement to contacts 1 and 4.
Vehicles 04.10 ?
–  Connect multimeter for voltage measurement to contacts 1 and 5.
For all vehicles
–  Activate remote control.
Specified value: approx. battery voltage.
If the nominal voltage is not reached:
–  Determine and remove open circuit in the wiring according to the current flow diagram → Current flow diagrams and Fitting locations.
If the nominal voltage is reached:
  A20-0099
–  Unscrew union nut with the wrench for union nut -MP1-227 (3217)-.
–  Remove fuel delivery unit and check whether the electric wiring between the flange and fuel delivery unit is connected.
If no open circuit was detected:
–  Replace fuel delivery unit → Chapter.
  S20-0054