Extractor, filler and measurement connections with Schrader valve > < Pressure relief valve
Extractor, filler and measurement valves for quick couplings of the service position on the refrigerant circuit
Extractor, filler and measurement valves for quick couplings of the service position on the refrigerant circuit
  WARNING
Before removing the extractor and filler valves, the refrigerant must be drained off with the aid of the A/C service station.
If the refrigerant circuit is not opened within 10 minutes after draining it off, pressure can arise in the refrigerant circuit due to the post-evaporation. Drain the refrigerant once again.
l  Only use valves and connections that are resistant to refrigerant R134a and related refrigerant oils.
l  Different connections (outside diameter) for the high-pressure and low-pressure side guarantee that the quick-coupling adapters are not interchanged.
l  After disconnecting the quick-coupling adapter tighten the caps to prevent any dirt from penetrating.
Special tools and workshop equipment required
   
t  Socket inserts -T10364-
Arrangement in the vehicle, see → Heating, Air Conditioning → Rep. gr.87.
  W00-10540

Extractor, filler and measurement connections with Schrader valve > < Pressure relief valve