Summary of components
   
Summary of components
  Note
The parts marked with an * must only be repaired in specialist service centres which have suitably trained personnel and are fitted out for working on the refrigerant circuit.
1 - Defroster vent
q   integrated in dash panel
2 - Sunlight penetration photosensor -G107-
q   Tasks: controls the temperature flap and the fresh air blower depending on the intensity of the sunlight
q   Emergency operation in the event of failure: the Climatronic control unit -J255- adopts the fixed value
q   removing and installing → Chapter
3 - Centre dash panel vent
q   with warning light switch
q   removing and installing → Chapter
4 - Dash panel
q   Removing and installing → Body Work; Rep. gr.70
5 - Side window vent
q   carefully lever out with disassembly wedge -3409-
6 - Outer dash panel vent
q   carefully lever out at top and bottom using the disassembly wedge -3409-
7 - Intermediate piece for dash panel vents
q   attached to heater unit with clips
q   for removing, take out dash panel
8 - Centre part of dash panel
q   Removing and installing → Body Work; Rep. gr.70
9 - Central pipe
10 - Intermediate piece for dash panel vents
q   attached to heater unit with clips
11 - Right footwell vent
q   bolted to heater unit (1.5 Nm)
12 - Air conditioning unit*
q   removing and installing → Chapter
q   disassembling and assembling → Chapter
13 - Connection part for rear duct
14 - Rear duct
15 - End piece for rear duct
q   clipped into rear duct and seat cross member
16 - Ventilation frames
q   clipped into rear cross member ahead of spare wheel well from outside
q   sealing lips must operate freely and close automatically
q   Area in front of ventilation frames must be clear otherwise ventilation of interior does not operate
17 - Left footwell vent
q   bolted to support (1.5 Nm)
18 - Gasket*
q   for connection of heat exchanger
q   in bulkhead (assembly plate)
q   Fitting position → Fig.
19 - Gasket*
q   for expansion valve connection
q   in bulkhead (assembly plate)
q   Fitting position → Fig.

   
Fitting location - gaskets
1 - Rubber seal for the bulkhead and the expansion valve
t  Mounting in bulkhead
2 - Bulkhead (assembly plate)
3 - Foam seal for the expansion valve and the bulkhead
t  stuck to evaporator housing
4 - Foam seal with holder - bulkhead
t  clipped in place on air-conditioning unit
5 - Valve for condensation water drain
t  installed in holder -4- and on the air conditioning unit
6 - Rubber gasket bulkhead - heat exchanger/valve for condensation water drain
t  Mounting in bulkhead
  S87-0112