| Press the sealing lip -3- of the gasket -6- all around the slot of the support -2- for the valve for condensation water drain -7--arrows-. |
–
| When installing the heat exchanger, press the sealing lip -4- of the gasket -6- all around the slot of the support -arrows- of the heat exchanger -5-. |
–
| Remove the cover for the bore holes of the expansion valve. |
–
| Replace O-rings of connection fitting of heat exchanger and expansion valve. |
–
| Connect coolant hoses the right way round. |
| In direction of travel on the left: Feed on the right: Return flow |
Note When closed the cover -1- must be flush with the heat-protection matting. If the cover -1- is pressed too far inwards, the cap of the valve for condensation water drain -7- may become stuck. |
–
| Inspect coolant level, top up with coolant if necessary. |
Note t
| If the heat exchanger was replaced, fill system with fresh coolant. |
–
| Fill the refrigerant circuit with the aid of the A/C service station. |
|
|
|