| Disconnect the feed hose -1- from the fuel filter inlet. |
–
| Connect pressure gauge -V.A.G 1318- with the adapter set -V.A.G 1318/17A- to the hose. |
–
| Repeat fuel flow rate test. |
If the minimum flow rate is now reached: |
If the minimum flow rate is again not reached: |
–
| Remove fuel delivery unit and inspect the filter strainer for soiling. |
If you have still not found any fault up to this stage: |
–
| Replace fuel delivery unit: |
If the required fuel delivery volume has been achieved, but a fault is still suspected in the fuel supply system (e.g. intermittent breakdown of the fuel supply): |
–
| Check power consumption of the fuel pump → Chapter. |
|
|
|