Switch on measuring range: resistance measurement (200 Ω)/(20 MΩ) |
Test step | -V.A.G 1598 A- bushes | Test covers | | Specified value | Measures for deviations from nominal value |
24 | - | Cables for solenoid coil for brake pressure -N247- | l
| Measuring range 200 Ω set |
–
| Pull out the multi-pin connector -T47a- from the ABS control unit -J104- |
–
| Connect test box -V.A.G 1598 A- with adapter -V.A.G 1598/33- |
–
| Disconnect plug connection T6x at brake servo unit |
–
| Check the following line connections for an open circuit: |
–
| Wiring of contact -T6x/4- (solenoid coil for brake pressure -N247-) via plug connection -T14c/7- with contact -T47a/17- (ABS control unit) |
| | |
–
| Wiring of contact -T6x/3- (solenoid coil for brake pressure -N247-) via plug connection -T14c/8- with contact -T47a/17- (ABS control unit -J104-). |
| max. 1.5 Ω | –
| Test wiring for open circuit. |
|
l
| Measuring range 20 MΩ set |
–
| Check cables for short-circuit to positive or to earth |
| ∞ Ω | |
|
|
l
| Measuring range 200 Ω set |
–
| Disconnect multi-pin connector T14c |
–
| Check contacts -7- and -8- in the plug connection -T14c- to the solenoid coil for brake pressure -N247- |
| 1.0 ... 2.0 kΩ | –
| The brake servo unit must be replaced if the specified value is not reached → Chapter. |
|