Meaning of 3-digit numerical block in display fields 1 and 2: > < Read out measured value block, display groups 030...049, 099 - Lambda control
Display group 030 - lambda control
   
Display group 030 - lambda control
l  Engine runs in idling speed
Read measured value block 30 →⇐ Readout on display  
xxxxxx     
1234⇐ Display fieldsSpecification
Analysis
     ------
    ------
  Status lambda control downstream of catalytic converter
l  Catalytic converter temperature at least 400.0°C (display group 34, display field 2)
111 → Chapter
 Status lambda control upstream of catalytic converter111 → Chapter

  Note
t  The first position in the 3-digit numerical block changes initially between 0 and 1 (lambda probe heater OFF and ON).
t  For the status of the lambda control, either a 0 or a 1 can be displayed in the 3-digit numerical block.
t  Readout in display fields 1 and 2 is only set to value 1 once the catalytic converter temperature is more than 400°C (⇒ display group 34, display field 2).
   