| The vacuum box for the intake manifold switch-over must pull in, the shift linkage must go back again to its initial position -arrow-. |
If the change-over does not occur, perform the following tests: |
–
| Check variable intake manifold changeover valve -N156- (perform final control diagnosis → Chapter, if necessary check valve and actuation → Chapter). |
–
| Inspect vacuum lines for proper connection, leaktightness and continuity. |
–
| Check smooth operation of changeover mechanism. (Operate shift linkage by hand.) |
|
|
|