Octavia Mk1
Display group 062, Electronic throttle system |
| |||||||||
Reading measured value block 62 | → | ⇐ Readout on display | |||||||
xx % | xx % | xx % | xx % | ||||||
1 | 2 | 3 | 4 | ⇐ Display fields | Specification | Analysis | |||
Sender 2 for accelerator pedal position - G185- | 0...100 % | --- | |||||||
Sender 1 for accelerator pedal position -G79- | 12...97 % | --- | |||||||
Throttle valve angle (potentiometer 2 -G188 -) | 97...3 % | --- | |||||||
Throttle valve angle (potentiometer 1 -G187-) | 3...93 % | --- |
Note
t | The engine control unit converts the voltage values of the accelerator pedal position sender in percentage (in relation to 5 Volts). A 5 V voltage supply corresponds to 100 %. |
t | If the accelerator pedal is fully pressed down, the specified value range changes. |
t | The value displayed in display field 3 must always be approximately double the value in display field 4. |