| Connect one contact of the valve -N156- with the connection line and alligator clip from -V.A.G 1594 A- to the engine mass. |
–
| Connect the second contact of the valve - N156- with remote control -V.A.G 1348/3A-, adapter cable -V.A.G 1348/3-2- and connection line to pos. term. |
–
| Activate the remote control -V.A.G 1348/3A- for 2 to 3 minutes. During this period, the vacuum unit must be connected. |
If the vacuum unit does not return to its initial position, check the vacuum unit as follows: |
–
| Disconnect vacuum lines from the vacuum unit for variable intake manifold changeover at “T”-union. |
–
| Connect hand vacuum pump -V.A.G 1390- to vacuum unit. |
–
| Actuate the hand vacuum pump and observe the switch over procedure. |
–
| Check vacuum unit for tightness. (The vacuum unit must not return to its initial position as long as it is not ventilated at the hand vacuum pump). |
–
| If necessary replace vacuum unit. |
If the vacuum unit does not connect, test valve -N156- for continuity as follows: |
–
| Connect one contact of the valve -N156- with the connection line and alligator clip from -V.A.G 1594 A- to the engine mass. |
|
|
|