Removing and installing control motor of fresh air flap and re-circulating air flap V154 >
< Removing and installing fresh air blower V2
Octavia Mk1
Heating, Air conditioning
Heating, Air conditioning / Heating / Repairing heating system
Removing and installing series resistor for fresh air blower N24
Removing and installing series resistor for fresh air blowerN24
Removing and installing series resistor for fresh air blower -N24 -
–
Remove screw clip for foam cover.
–
Swing foam cover
-C-
to the side.
–
Remove the connector
-A-
from the series resistor.
–
Release screws
-B-
and remove resistor carrier.
Remove series resistor from the resistor carrier
–
Bore out or break off attachments
-A-
.
–
Press back
-C-
catches.
–
Remove series resistor
-B-
.
–
Installation is carried out in the reverse order.
Note
When installing, fix series resistor with sheet metal screw
-D-
of 3.2x10 mm.