skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Regulating valve for compressor of air conditioning systemN280 > < Air conditioner pressure switchF129
High-pressure senderG65
   
High-pressure sender -G65-
  Note
The high pressure sender -G65- (specifically designed for vehicles) can be installed instead of the pressure switch for the air conditioning system -F129-.
The high-pressure sender -G65- determines the pressure in the refrigerant circuit and transmits the values to the Air conditioning system control unit -J301- or to the Climatronic control unit -J255-.
The following are shifted via these control units:
t  The radiator fan -V7- switches to the next speed in the event of a pressure rise in the refrigerant circuit
t  Reduction of the compressor output if the pressure is too high, 3.2 MPa (32 bar), e.g. too little engine cooling
t  Reduction of the compressor output if the pressure is too low, 0.2 MPa (2 bar), e.g. refrigerant loss
  S87-0233

Regulating valve for compressor of air conditioning systemN280 > < Air conditioner pressure switchF129