| Disconnect the pressure hose -arrow- from the secondary air pump motor -V101-. |
Note To unlock press together the buttons on the hose coupling. |
–
| Lightly blow into the hose line to the combination valve: |
l
| The combination valve must remain closed. |
–
| Strongly blow into the hose line to the combination valve: |
l
| The combination valve should open. |
If the combination valve does not open or is constantly open: |
–
| Replace combination valve. |
|
|
|