| Release screws -1- for connection pipe for exhaust gas recirculation. |
–
| Remove vacuum hose -2- from vacuum setting element and expose. |
–
| Release screws -arrows- and remove radiator for exhaust gas recirculation. |
Installation occurs in reverse order to removal. Pay attention to the following: |
t
| Replace the gaskets, the sealing rings and the self-locking nuts. |
t
| Secure all hose connections with corresponding hose clips. |
–
| Inspect coolant level and top up if necessary → Chapter. |
|
|
|