skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Checking fuel flow rate with pressure gaugeVAS 6550 > < Checking holding pressure with pressure gaugeVAS 6550
Checking fuel flow rate with pressure gaugeV.A.G 1318
Checking fuel flow rate with pressure gauge -V.A.G 1318-
  Note
t  Safety precautions when working on the fuel supply system → Chapter.
t  Rules of cleanliness when working on the fuel supply system → Chapter.
–  Switch off the ignition and all electrical components and take out the ignition key.
For the vehicles Fabia II
–  Position right rear seat vertically → Body Work; Rep. gr.72.
For the vehicles Roomster
–  Fold back the middle and rear seat and position vertically → Body Work; Rep. gr.72.
For the vehicles Octavia II
–  Removing rear seat bench → Body Work; Rep. gr.72.
For the vehicles Yeti
–  Remove rear seat bench with brackets → Body Work; Rep. gr.72.
–  Remove floor covering under the rear seat bench.
For the vehicles Fabia II, Roomster
   
–  Unclip the cover -1- with the fuel pump control unit -J538--2-.
For the vehicles Octavia II, Yeti
  N20-0603
–  Unclip the cover -4- with the fuel pump control unit -J538--1-.
Continued for all vehicles
  S20-0159
–  First of all check the plug -1- for correct fit. To do so, pull on the plug without pressing the catch. If the plug was not correctly plugged in, it may have caused a fault.
–  Now unplug the plug -1-.
–  Check the contacts at the plug and at the fuel delivery unit for damage.
  M20-0232
–  Connect the adapter for measuring method/DSO (5-pin) -VAS 5565- to the plug and to the fuel delivery unit.
–  Connect the remote control -V.A.G 1348/3A- to the adapter -VAS 5565- and to the battery positive (+).
  Note
This step is only intended to ensure that the fuel delivery unit runs when the engine is switched off.
For the vehicles Fabia II, Roomster
  N20-10422
–  Remove the fuel feed line -3- (press in the securing ring to the top) and catch the fuel which flows out with a cleaning cloth.
For the vehicles Octavia II, Yeti
  S10-0431
–  Remove the fuel feed line -1- (press in the securing ring to the top) and catch the fuel which flows out with a cleaning cloth.
Continued for all vehicles
  N10-10317
–  Connect the pressure gauge -V.A.G 1318- with the double connection piece -V.A.G 1318/23- and the adapter set -V.A.G 1318/17A- to the fuel feed line.
–  Fit the hose adapter -V.A.G 1318/16- onto the adapter -V.A.G 1318/11- of the pressure measuring device and hold it in a measuring glass.
–  Close the shut-off cock of the pressure measuring device. The lever then points in the position -B-.
  WARNING
Danger of liquid spraying out when opening the shut-off valve. Wear safety goggles and safety clothing, in order to avoid injuries and skin contact with fuel. Hold the container in front of the free connection to the pressure gauge.
–  Open shut-off cock of the pressure gauge. The lever then points in the direction of flow -A-.
–  Activate remote control -V.A.G 1348/3A-. While doing so, slowly close the shut-off cock until the pressure gauge displays 0.4 MPa (4 bar) overpressure. Now do not make any further changes to the position of the shut-off cock.
–  Empty measuring glass.
  N20-0611
–  The fuel flow rate of the fuel pump is dependent on the battery voltage. For this reason, additionally connect the multimeter -V.A.G 1715- to the outgoing circuits -1 and 5- of the adapter for measuring method/DSO (5-pin) -VAS 5565-.
–  Activate remote control for 30 seconds while measuring the battery voltage.
  N20-10423
–  Compare the fuel rate with the specified value.
*) minimum flow rate 1 cm3/30 s
**) Voltage at fuel delivery unit when engine not running and delivery unit operating (approx. 2 volts less than battery voltage)
Read out examples:
During the test a voltage of 12.5 V was measured on the battery. As the voltage on the fuel pump is approximately 2V less than the battery voltage, a minimum flow rate of 580 cm 3/30 s is obtained.
If the minimum flow rate is not reached:
–  Check the fuel lines for possible restrictions (kinks) or blocking.
If no fault is found:
  S20-0268
–  Disconnect the feed hose -1- from the fuel filter inlet.
–  Connect pressure gauge -V.A.G 1318- with the adapter set -V.A.G 1318/17A- to the hose.
–  Repeat fuel flow rate test.
If the minimum flow rate is now reached:
–  Replace fuel filter.
If the minimum flow rate is again not reached:
–  Remove fuel delivery unit and inspect the filter strainer for soiling.
If you have still not found any fault up to this stage:
–  Replace fuel delivery unit:
t  Fabia II, Roomster → Chapter.
t  Octavia II, Yeti (version l.) → Chapter.
t  Yeti (version II.) → Chapter.
If the required fuel delivery volume has been achieved, but a fault is still suspected in the fuel supply system (e.g. intermittent breakdown of the fuel supply):
–  Check power consumption of the fuel pump → Chapter.
  S20-0172

Checking fuel flow rate with pressure gaugeVAS 6550 > < Checking holding pressure with pressure gaugeVAS 6550