l
| At a vacuum of 0.005...0.012 MPa (0.05…0.120 bar) the tension rod must move up. |
l
| At a vacuum of 0.055...0.062 MPa (0.550…0.620 bar) the tension rod must rest at the top against the stop. |
–
| Remove the connecting hose from the hand vacuum pump -VAS 6213- and at the same time observe the tension rod over the entire adjustment range. |
l
| The tension rod must move without jolting over the entire adjustment range. |
If the specified values are not achieved or the tension rod moves with jolt: |
Note t
| If the measuring accuracy of the vacuum using the hand vacuum pump -VAS 6213- is not adequate, the turbocharger tester, e.g. -V.A.G 1397 A-, can be used for a more precise measurement. -V.A.G 1397 A-. |
|
|
|