| Connect the prepared, well cleaned adapter to the high pressure connection piece of the high pressure pump to 20 Nm. |
–
| Connect the hand vacuum pump -VAS 6213- with the prepared adapter. |
–
| Using the hand vacuum pump -VAS 6213-, generate a pressure of min. 1 bar. |
If the high pressure pump is O.K, the pressure remains constant for more than 30 s. |
If the high pressure pump is defective, the pressure drops again within 2 ... 3 s to 0 bar. |
If necessary repeat the test, pay attention to the pressure loss on the hand vacuum pump -VAS 6213-. |
|
|
|