Hose connections with screw clamps |
Note t
| Connections, charge air pipes and hoses of charge air system must be free of oil and grease before being installed. |
t
| In order to secure the charge air hoses on their connection fittings, the threads must be treated with rust solvent if the screw clamps have been used beforehand. |
t
| After a repair, check all the charge air pipes, charge air hoses and vacuum lines for tight connection and leaktightness. |
Caution The screw clamps -A- on the charge air hoses must definitely be precisely tightened in accordance with the specifications → Fig.. |
A too low or on the contrary, a too high tightening torque of the screw clamps, may result in the charge air hose slipping off the fluted pipe or the charge air pipe while driving. |
|
|
|
|