Testing coolant thermostat
Testing coolant thermostat
–
Heat up the removed 4/2 way valve with coolant regulator in a water bath.
Start of opening
Full opening
Stroke
approx. 87 °C
approx. 102 °C
1)
min. 8 mm
1)
Cannot be tested.