In order to collect flowing out coolant, place a cloth below the coolant recirculation pump 2 -V178-. |
–
| Pinch off the coolant hoses with hose clamps up to a diameter of 25 mm -MP7-602-, slacken spring strap clamps -3- and detach the hoses. |
–
| Release screws -1- and remove coolant recirculation pump 2 -V178-. |
Installation is performed in the reverse order, pay attention to the following points: |
Note t
| Connections as well as charge air pipes and charge air hoses must be free of oil and grease before being installed. |
t
| Observe the instructions for installing the charge air hoses and tightening torques of the screw clamps → Chapter. |
–
| Inspect coolant level, top up with coolant if necessary → Chapter. |
|
|
|