smart Workshop Repair Guides

Smart Workshop Service and Repair Manuals

GF54.30-P-0002MCU Instrument cluster (IC), function|Page 3116 > < GF54.30-P-0002MCU Instrument cluster (IC), function|Page 3114
Page 2
background image

^

One wrench = Oil service plus

^

Two wrenches = Maintenance

The left button on the instrument cluster can be used to confirm the display on the maintenance interval display.
The maintenance interval display is shown for 10 s by briefly pressing the button in the right of the instrument cluster twice. 

Trip odometer

The display area for the trip odometer is 0 to 9999.9 kilometers or miles (with code (K07) Speedometer (miles)). Once the maximum reading is reached
the display is automatically reset to zero.

Manual reset:
Keep pressing the left button until the trip odometer appears in the multifunction display. After pressing the left button again for 1 s the display starts to
flash on and off. Continue to press and hold the left button. The display is reset to zero.

The trip distance remains stored even when the battery (G1) is disconnected.

Odometer

The main odometer reading is shown either in kilometers or miles, as soon as the instrument cluster is activated.
The range for the main odometer is from 0 to 999,999 kilometers or miles. If the maximum mileage is reached, the counter is not reset to zero.
In this case, the instrument cluster should be replaced. The internal counter continues to operate however. The main odometer reading is stored for at
least 10 years, even if the voltage supply is disconnected.

Outside temperature indicator

The instrument cluster takes the following data into consideration when determining the outside temperature value:

^

Outside temperature value directly from outside temperature display temperature sensor (B14)

^

Internal vehicle speed signal from instrument cluster

^

Coolant temperature value via CAN from the ME-SFI [ME] control unit

^

Engine running time over CAN from ME-SFI [ME] control unit

The instrument cluster processes this data and actuates the outside temperature indicator accordingly.

The dependency of the outside temperature indicator on the speed, the engine running time and the coolant temperature prevents too high a temperature
being displayed through radiant heat when the vehicle is stationary or moving slowly. Falling temperature values are always allowed.

The display's response pattern varies as temperature rises, according to coolant temperature and engine running time:

^

Coolant temperature < 60 °C:
The current outside temperature value is always displayed when the instrument cluster is activated.

^

Coolant temperature > 60 °C:
When the instrument cluster is activated rising outside temperature values are displayed with a delay.

^

Coolant temperature > 60 °C and circuit 15 OFF:
The last measured temperature value is stored for a period of t = 60 min. When the instrument cluster is activated, the stored temperature value is
shown in the outside temperature display.

If the coolant temperature sensor (B11/4) is defective or if it provides implausible coolant temperature value, the ME-SFI [ME] control unit sends a
corresponding message over CAN to the instrument cluster. A coolant temperature of >= 60 °C is assumed.

Set the time

After pressing the left button on the instrument cluster for > 5 s the colon in the time display starts to flash on and off. Now the left button or the right
button can be used to set the time.

If one of the two buttons is not pressed again within the next 5 s, the set value is stored and the colon stops flashing.

GF54.30-P-0002MCU Instrument cluster (IC), function|Page 3116 > < GF54.30-P-0002MCU Instrument cluster (IC), function|Page 3114