11

Squeeze crimp pliers until stop is reached remove crimped connection.
The manual crimp pliers must be squeezed until stop is reached before they will open again.

12

Check crimp connection for correct deformation and filling.
Correct crimp connection (A): The strands of the line are evenly enclosed. The crimp tab is evenly shaped.
Incorrect crimp connections (B, C, D): The crimp tab has an incorrect cross section. The crimp tab is not filled properly. Individual wire strands
are outside the crimp shackle. The crimp tab is too full. The crimp claws touch the bottom of the crimped fitting. The crimp tab is too full. The
crimp tab is deformed and therefore damaged.