ForTwo L3-1.0L (2009)
2
Using a suitable tool (1), slide retaining cage (2) into pre-locking position in direction shown by arrow.
Unpin female contacts from coupling
3
Insert blade holder with clamping pliers and MQS blade from front side through opening next to contact cavity of coupling.
This step presses the spring shackle on the female contact (1) down into position.
4
A slight tug on the corresponding cable will remove the female contact (1) from the contact cavity of the coupling.
AR00.19-P-0120-05A Remove contacts from E 95 coupling
AR00.19-P-0120-05A Remove Contacts From E 95 Coupling