subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Trunk / Liftgate > < Doors, Hood and Trunk|Adjustments|Page 4193
Page 2
background image

INSTALLATION

1. Install in the reverse order of removal.
2. Adjust clearance between hood and fender. Clearance must be equal at both sides.

Tightening torque: 24.5 N.m (2.5 kgf-m, 18.1 ft-lb)