Battery: Testing and Inspection

INSPECTION

WARNING:

-

Electrolyte has toxicity; be careful handling the fluid.

-

Avoid contact with skin, eyes or clothing. Especially at contact with eyes, flush with water for 15 minutes and get prompt medical
attention.

-

Batteries produce explosive gases. Keep sparks, flame, cigarettes away.

-

Ventilate when charging or using in enclosed space.

-

For safety, in case an explosion does occur, wear eye protection or shield your eyes when working near any battery. Never lean over a
battery.

-

Do not let battery fluid contact eyes, skin, fabrics, or paint-work because battery fluid is corrosive acid.

-

To lessen the risk of sparks, remove rings, metal watch-bands, and other metal jewelry. Never allow metal tools to contact the positive 
battery terminal and anything connected to it while you are at the same time in contact with any other metallic portion of the vehicle
because a short circuit will be caused.

EXTERNAL PARTS:

Check for the existence of dirt or cracks on the battery case, top cover, vent plugs, and terminal posts. If necessary, clean with water and wipe with a dry
cloth.
Apply a thin coat of grease on the terminal posts to prevent corrosion.

ELECTROLYTE LEVEL:

Check the electrolyte level in each cell. If the level is below MIN LEVEL, bring the level to MAX LEVEL by pouring distilled water into the battery
cell. Do not fill beyond MAX LEVEL.

SPECIFIC GRAVITY OF ELECTROLYTE:

1. Measure specific gravity of electrolyte using a hydrometer and a thermometer. Specific gravity varies with temperature of electrolyte so that it

must be corrected at 20 °C (68 °F) using the following equation:

S20 = St + 0.0007 x (t - 20)

S20: Specific gravity corrected at electrolyte temperature of 20 °C
St: Measured specific gravity
t: Measured temperature ( °C)
Determine whether or not battery must be charged, according to corrected specific gravity.
Standard specific gravity: 1.220 - 1.290 [at 20 °C (68 °F)]

2. Measuring the specific gravity of the electrolyte in the battery will disclose the state of charge of the battery. The relation between the specific

gravity and the state of charge is as shown in figure.

MEASUREMENT

WARNING:  Do not bring an open flame close to the battery at this time.

CAUTION:

-

Prior to charging, corroded terminals should be cleaned with a brush and common baking soda solution.

-

Be careful since battery electrolyte overflows while charging the battery.

-

Observe instructions when handling battery charger.

-

Before charging the battery on vehicle, disconnect battery ground terminal. Failure to follow this rule may damage alternator's diodes or other
electrical units.

Electrical - Low Battery Voltage Affects Other Systems|Page 3403 > < Electrical - Low Battery Voltage Affects Other Systems|Page 3401