Alarm Module: Testing and Inspection
Security Control Unit

Security Control Unit

PROCEDURE

1. FUNCTION SETTING (ECM CUSTOMIZING)

1. Connect the Subaru Select Monitor to the data link connector.
2. Turn the ignition switch to ON.
3. On the <<Main Menu>> display screen, select the {Each System Check} and press the [YES] key.
4. On the <<System Selection Menu>> display screen, select the {keyless unit mode} and press the [YES] key.
5. On the <<Keyless Unit Mode>> display screen, select the {ECM customizing} and press the [YES] key.

6. Change the setting with UP/DOWN key and press the [YES] key.

-

List of function setting item (ECM customizing)

7. After setting, make sure that vehicle equipment matches the changed settings in the {Current Data Display & Save}.

CAUTION:
-

The above settings most match the actual vehicle equipment for proper operation.

-

Do not change settings other than the above while setting equipment.

-

When installing a new keyless unit, perform initial setting again.

-

In passive mode, the system will automatically activate the security alarm but WILL NOT automatically lock the doors. Failure to lock the
doors manually will result in a high security risk.

NOTE:  For details concerning operation procedure, refer to the "SUBARU SELECT MONITOR OPERATION".

8. Turn the ignition switch to OFF, and then remove the Subaru Select Monitor.

2. WARNING HISTORY NOTICE MODE

1. Turn the ignition switch to ON.