Forester F4-2.5L SOHC (2004)
1. Install in the reverse order of removal.
CAUTION: Replace the O-rings on hoses or pipes with new ones, and then apply compressor oil. Confirm that lower guide of condenser has
been fitted into holes on radiator panel.
2. Charge refrigerant.
INSPECTION
1. Confirm that no dust or insects are found on the condenser fins. Air-blow or flush fins with water as needed.
2. Confirm that no oil leaks from condenser. If a failure is found, replace the condenser with a new one.