Alternator: Electrical Specifications

Generator

Output Current 

1,500 rpm .........................................................................................................................................................................................  36 Amps or more
2,500 rpm .........................................................................................................................................................................................  65 Amps or more
5,000 rpm .........................................................................................................................................................................................  86 Amps or more

Regulated Voltage

14.1 - 14.8 Volts .......................................................................................................................................................................  (20 deg. C / 68 deg. F)