Forester F4-2.5L SOHC (2004)
20. Disconnect the duty solenoids and ATF temperature sensor connectors. Remove the connectors from clip and disconnect the connectors.
21. Remove the harness assembly.
INSTALLATION
1. Pass the harness assembly through the hole in the transmission case.
2. Connect the harness connectors. Connect the connectors of same color, and secure the connectors to valve body using clips.
Tightening torque (Transmission ground cable) 8 Nm (0.8 kgf-m, 5.8 ft. lbs.)