Leak Detection Solenoid: Service and Repair

Pressure Control Solenoid Valve

REMOVAL

1. Set the vehicle on a lift.
2. Disconnect the ground cable from the battery.

3. Lift up tine vehicle.
4. Disconnect connector (A) from tine pressure control solenoid valve.
5. Disconnect the evaporation hose (B) from the pressure control solenoid valve.
6. Remove the bolts (C) which secure the bracket to the fuel tank.

7. Remove the pressure control solenoid valve and bracket as a unit.
8. Remove the pressure control solenoid valve from the bracket.

INSTALLATION

Install in the reverse order of removal.

Tightening torque: 7.35 N.m (0.7 kgf.m, 5.4 ft.lb)