Forester AWD F4-2.5L DOHC (1998)
Air Cleaner Housing: Service and Repair
AIR CLEANER AND AIR INTAKE DUCT
REMOVAL AND INSTALLATION
1) Disconnect battery ground cable.
2) Disconnect connector from mass air flow sensor.
3) Loosen clamp which connects air intake duct to air intake chamber.
4) Remove two clips of air cleaner upper cover.
5) Disconnect blow-by hose from air intake duct.
6) Remove air intake duct and air cleaner upper cover as a unit.
7) Remove air cleaner element.