Expansion Valve: Description and Operation

Expansion Valve

MECHANISM

The expansion valve is attached to the evaporator inlet and outlet pipe. It converts high pressure liquid refrigerant which comes from the liquid tank to
misty, low pressure refrigerant, and delivers to the evaporator. Being at low pressure and low temperature, the liquid refrigerant evaporates in the
evaporator removing heat from the compartment. It automatically controls the flow rate of refrigerant to obtain the necessary cooling ability required by
the fluctuating heat load.

The refrigerant temperature is sensed by the temperature sensing element installed at the low pressure refrigerant passage in the expansion valve, and the
flow rate of the refrigerant is controlled by changing the lift of the valve ball at the high pressure side.

FUNCTION

If the heat load of the air conditioner system increases, the refrigerant temperature at the evaporator outlet rises and therefore increases the pressure P1 at
around the temperature sensing area. As this pressure P1 becomes higher than the resultant force of evaporator outlet (low pressure side) pressure P2 and
the spring force F (P1 > P2 + F), the diaphragm is pressed down, opening the valve ball connected to the diaphragm to increase the flow of the
refrigerant.

If the heat load decreases, the action contrary to the one mentioned above takes place, closing the valve to decrease the flow of the refrigerant.