Air Door Position Sensor / Switch: Testing and Inspection

Microswitch

Microswitch

1.

Remove front shelf and air duct.

2.

Remove microswitch with bracket.

3.

Check switch operation with ohmmeter:

a. With switch free, there should be no continuity.
b. With switch depressed, meter should indicate continuity.

4.

If not as specified, replace switch.