subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Thermo Vacuum Valve-2 Port|Page 1304 > < Fuel Separator - Production Change|Page 1299
Page 1
background image

Thermal Vacuum Valve - EVAP: Testing and Inspection
Thermo Vacuum Valve-2 Port

1.

Connect hoses to the 2 ports.

2.

Submerge valve in water and heat gradually. Do not allow water to get into the valve.

3.

If the valve is not completely open below 57 deg. F. and completely closed above 68 deg. F., replace the valve.

Thermo Vacuum Valve-2 Port|Page 1304 > < Fuel Separator - Production Change|Page 1299