subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Specifications|Page 5307 > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation

PRESSURE SWITCH

The pressure switch is a high-pressure side component of the refrigeration cycle (cooling cycle). It consists of a diaphragm that receives refrigerant gas
pressure, a snap plate, a rod, and contacts that open both when the gas pressure is too low and when it is too high.

The pressure switch plays the following roles:

-

Preventing "no-gas" operation due to leakage (when gas pressure is too low)

-

Protecting the cooling system against abnormally high refrigerant pressure (when gas pressure is too high)

ON-OFF pressures

Refrigerant Pressure with Manifold Gauge Set

OPERATION

1. Place the vehicle in the shade and draftless condition.
2. Connect the manifold gauge set.
3. Open the front windows and close all doors.
4. Open the hood.
5. Increase the engine to 1,500 rpm.
6. Turn ON the A/C switch.
7. Turn the temperature control switch to MAX COOL.
8. Put in RECIRC position.
9. Turn the blower control switch to HI.

10. Read the gauge.

Standard:
-

Low pressure: 127 - 196 kPa (1.3 - 2.0 kg/sq.cm, 18 - 28 psi)

-

High pressure: 1,471 - 1,667 kPa (15 - 17 kg/sq.cm, 213 - 242 psi)

-

Ambient temperature: 30 - 35 °C (86 - 95 °F)