subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Front Oxygen (A/F) Sensor|Page 2336 > < Front Oxygen (A/F) Sensor|Page 2334
Page 1
background image

Oxygen Sensor: Service and Repair
Rear Oxygen Sensor

REMOVAL

1. Disconnect the battery ground cable.
2. Lift-up the vehicle.

3. Disconnect the connector from the rear oxygen sensor.
4. Apply SUBARU CRC or its equivalent to the threaded portion of rear oxygen sensor, and leave it for one minute or more.

SUBARU CRC (Part No.004301003)

5. Remove the rear oxygen sensor.

CAUTION:  When removing the oxygen sensor, wait until exhaust pipe cools, otherwise it will damage exhaust pipe.

INSTALLATION

1. Before installing rear oxygen sensor, apply the anti-seize compound only to the threaded portion of rear oxygen sensor to make the next removal

easier.

CAUTION:  Never apply anti-seize compound to protector of rear oxygen sensor.

Front Oxygen (A/F) Sensor|Page 2336 > < Front Oxygen (A/F) Sensor|Page 2334