subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Diagnosis and Testing|Page 3452 > < Diagnosis and Testing|Page 3450
Page 3
background image

3. Insulation resistance of brush holder 

Be sure there is no continuity between brush holder and its plate.

4. Brush spring force

Measure brush spring force with a spring scale. If it is less than the service limit, replace brush spring.

Brush spring force:
Standard: 18.6 N (1.9 kg, 4.2 lb) (when new) 
Service limit: 6.9 N (0.7 kg, 1.5 lb)

5. SWITCH ASSEMBLY

Be sure there is continuity between terminals S and M, and between terminal S and ground. Use a circuit tester (set in "Ohm").

Also check to be sure there is no continuity between terminal M and B.

Terminal / Specified resistance:
S - M / 10 Ohm, max.
S - Ground / 10 Ohm max.
M - B / 1 MOhm, min.

Diagnosis and Testing|Page 3452 > < Diagnosis and Testing|Page 3450